Innocor®
Advanced cardiopulmonary and lung function testing using inert gases
OVERVIEW
Innocor® provides non-invasive measurement of cardiac output at rest and during exercise by inert gas rebreathing (Innocor® CO), and lung clearance index measurement from preschool children to adults via multi-breath SF6 wash-out technique (Innocor® LCI).
The simplicity of the test manoeuvres together with the specifically designed patient interfaces make the tests suitable for both adults and children.
For both methods, Innocor® utilizes a fast-responding photoacoustic infrared gas analyser which guarantees unmatched sensitivity, accuracy, and stability. Innocor® is validated in an impressive number of papers covering diverse conditions.
FDA 510(k) Cleared
Available For US Market only
DOWNLOAD
KEY FEATURES
Non-invasive cardiac output
Inert gas rebreathing is an accurate, reproducible, and rapid method relying on an analytical principle based on a sound lung model using insoluble gas (SF6) distribution and blood soluble gas (N2O) uptake.
Lung Clearance Index
Ventilation distribution analysis (LCI, FRC) is done via multi-breath wash-out using true insoluble tracer gas SF6 ensuring no N2 back diffusion, O2 influence on breathing or effect of inspiratory leakages.
Metabolic gas exchange option
Cardiac output can be combined with metabolic measurements during cardiopulmonary exercise testing by breath-by-breath gas exchange analysis.
Outstanding accuracy
The patented fast-responding photoacoustic infrared multi-gas analyser guarantees high sensitivity, accuracy, and reliability in measuring SF6, N2O, and CO2.
Daily calibration not required
Photoacoustic gas analysis ensures unmatched stability which means that Innocor® only requires a yearly calibration check.
Compact and portable design
Reduced dimensions and the integration of the miniature gas cylinder allow to easily move Innocor® in between departments.
Versions
INNOCOR CO
Non-invasive Cardiac Output (CO) measurement
- Inert gas rebreathing with integrated gas cylinder
- Assess hemodynamic and cardiovascular impairment
- Optional breath-by-breath gas exchange analysis module
- Optional LCI assessment by SF6 rebreathing module
- Suitable for adults and children at rest and during exercise
- Daily calibration not required
INNOCOR LCI
Lung Clearance Index (LCI) measurement
- Multibreath wash-out (MBW) with SF6 gas mixture
- Detect early peripheral airway damage in cystic fibrosis (CF) patients
- Optional breath-by-breath gas exchange analysis module
- Optional Cardiac Output (CO) assessment module
- High sensitivity from preschool children to adults
- No need for external O2 supply (integrated test gas cylinder).
Related products
View other similar and compatible products
LUNG FUNCTION
Full modularity and networking for truly customised Lung Function testing solutions
METABOLIC CART
Metabolic cart for cardio pulmonary exercise testing in clinical applications
STRESS TESTING ECGS
Diagnostic quality 12-lead Stress testing ECG in cable or telemetry configuration
Gallery